Device Mega Laser 808 progressive...
Device Mega Laser 808 progressive...
Device Mega Laser 808 progressive...
Device Mega Laser 808 progressive...
Device Mega Laser 808 progressive...
Device Mega Laser 808 progressive hair removal treatment
Device Mega Laser 808 progressive hair removal treatment
Device Mega Laser 808 progressive hair removal treatment
Device Mega Laser 808 progressive hair removal treatment
Device Mega Laser 808 progressive hair removal treatment

Device Mega Laser 808 progressive hair removal treatment

9156
OUT OF STOCK 0
€30,129.00
Tax included

 

Mega Laser 808

GOODBYE IRRITATIONS AND INGROWN HAIRS

SUITABLE FOR ANY SKIN TYPE EVEN IF TANNED

FOR FACE AND BODY HAIR REMOVAL TREATMENTS:

·         REALLY PAINLESS WITH INNOVATIVE SHR SYSTEM

·         EFFECTIVE

·         COMFORTABLE

·         QUICK

 

New handpiece holder design: more resistant, with non-slip rubber for safe placement of the handpiece

 

Long life control system: advanced polarization of the laser diodes for longer life and high performance

Laser beam emission light indication

SHR (Super Hair Removal) System

Painless initial thinning, through the automatic use of low fluences and high frequencies.

SHR gradually overheats the hair, reaching the goal and, at the same time, accustoms the skin to the heat, minimizing the sensation of pain.

After having taken the client's medical history and selected the area to be treated, Mega Laser 808 automatically sets the correct parameters to be used for the PAINLESS TREATMENT.

The SHR mode is recommended for initial hair thinning (first 1-2 sessions) for a PAINLESS TREATMENT and EFFECTIVE AND IMMEDIATELY VISIBLE HAIR REDUCTION.

Afterwards, it is recommended to switch to work mode without using the SHR method .

 

Strength points

Profitability

Profit

The high profitability of the treatment allows high earnings for the Institute. This is also thanks to the possibility of integrating multiple hair removal treatments on different parts of the body, even in the same session.

Greater revenue!

Speed

Speed of execution = time saving for the Client, who has less and less time available.

Functionality and efficiency

Safety

Software for use and control of functions with built-in medical history + Quality of the materials used + Tested protocols, allow you to work for 12 months a year, even on tanned skin.

Comfortable

Painless treatment with SHR protocol

Targeted

Thanks to the new front tip of the handpiece, excellent results even on difficult areas such as elbows, knees, chin, moustache...

Avant-garde and design

Nothing is left to chance, design and ergonomics are the "skin" that contains technology at the highest level.

Super operator advantages

Innovative technology that improves comfort and light absorption

No topical anesthetic or secondary cooling is required

Reduction of treatment times by approximately 75%

Reduction of treatment cycles by approximately 40%

 Possibility to treat (with caution) even darker phototypes

Super customer benefits

Much faster treatments, better planning of your time

More comfortable treatments that encourage the client's approach to the system and convince him to continue until its completion

The treatment cycle (much faster than previous technologies) improves results and satisfaction

The speed of execution makes even the largest areas (legs, back, etc.) accessible for time and money.

No sensation of pain with SHR protocol

Technical features

·         Source: diode laser

·         Wavelength: 808nm (nanometers)

·         Laser power: 600 Watts

·         Handpiece spot size: 14 x 14mm (196mm²)

·         Working mode: both single and multiple spots from 1 to 10 per second

·         Fluence: 1÷40 J

·         Energy density: Max 40 J/cm²

·         Spot cooled area: -5°C to +5°C (adjustable)

·         Handpiece Head Cooling: with Peltier Cells (Safe and Innovative Technology)

·         Laser emission system: Button + Pedal

·         Screen: 11.6” Full HD color touch-screen with adjustable tilt

·         Number of laser bars: 12 bars of 50W each.

·         Time per session: Reduced times per area. Example: 4/6 min.

·         Pulse Speed: Up to 10 spots second.

·         Number of seats per area: From 5 to 7.

·         Phototypes treated: All up to VI°.

·         Cooling: Integrated circuit water.

·         Handpiece cooling: Peltier cells (safe and innovative technology) + water and air.

·         Handpiece life: Up to 10,000,000 spots* (carried out at average power value).

·         Seasonal Frequency: 12 months a year.

·         Effects on the skin: painless with SHR SYSTEM.

·         Environment in the Institute: No odor.

Technical data

·         Power supply: 220 - 240V ~ 50/60Hz – 2200W

·         Appliance dimensions: 59x40x41h cm

·         Device dimensions with mounted handpiece holder: 59x46.5xh 41 cm

·         Packaging dimensions: 73x50xh 58.5 cm

·         Appliance weight: 36.5kg

·         Appliance weight with packaging: 50kg

Features
Laser epilation procedures
Usage
For face and body care

This confirms the role of Italian-made manufacturing both in Italy and abroad. Our growth is essentially encapsulated in the constant evolution of products and solutions that meet customers’ expectations. Every day we commit ourselves to giving our all in what we do, driven by our know-how to achieve new goals. Care for detail and creating first-class products fully express our vocation for meeting the needs of our clientele.

You might also like

Grade Comments (0)

No customer reviews for the moment.
Product added to wishlist
Product added to compare.

Interneta vietnes, tai skaitā veikali izmanto sīkdatnes ( angļu val.cookies ), lai sniegtu labāko un ātrāko servisu. Sīkdatnes uzkrāj anonīmus datus par vietnes apmeklējumu un palīdz radīt ērtāku lietošanas pieredzi. Mēs izmantojam sīkdatnes. Lietojot šo vietni, Jūs apstiprināt, ka saprotat un piekrītat sīkdatņu izmantošanai Jūsu ierīcē.